Description
(NEW) DEFR Wiggins Fast Fueling Systems | Receiver- DEF Fill Systems
FEATURES:
- Automatic Shutoff
- 114 lpm (30 gpm) flow rate
- Does not pressurize tank
- Can be filled from remote fill point
- Contamination minimized
- Parts are made from 304/316 stainless steel or plastic to help with corrosion from DEF fluids
- DEF freezes at -11°C (+12°F)
Design Challenges:
- Tanks, hoses and fittings must be prevented from freezing
- Receiver and Automatic Shutoff Valve have internal heaters
- Transfer hose between Receiver and Automatic Shutoff Valve must be heated or drained
- System must be designed to minimize exposure to air
- Vent has check valves to minimize exposure of tank to outside air
- Receiver and nozzle have self-sealing valves that close upon disconnection
COMPONENTS OF SYSTEM:
- Receiver – DEFR
- automatic Shutoff Valve – DEFVALVEHR
- Vent – DEFVENT
- Nozzle – DEFN
WARNING: Some metal products may contain elements or chemicals known to the State of California to cause cancer, birth defects, or reproductive harm. These elements include but are not limited to Chromium, Cobalt, Lead, and Nickel. For more information visit www.P65Warnings.ca.gov